Management actions to maintain means of escape Once the means of escape have been identified within a building
0
Comments
Management actions to maintain means of escape Once the means of escape have been identified within a building
Umer Naqqash
June 18, 2018
7.21 Management actions to maintain means of escape Once the means of escape have been identified within a building, there remains an outri...
Emergency lighting units should be sited to cover specific areas, such as intersections of corridors, at each exit door, near each staircase...
Requirements for escape stairs, passageways and doors This subject is dealt with in great detail in The Building Regulations 2000 Fire Safe...
The two illustrations depict ventilators that have automatically opened and essentially a chimney effect is created in the ventilation shaft...
When assessing the adequacy of the means of escape you will need to take into account
Umer Naqqash
June 18, 2018
When assessing the adequacy of the means of escape you will need to take into account: • the findings of your fire risk assessment; • the ...
Flame Retardant Treatments
Umer Naqqash
June 18, 2018
Flame Retardant Treatments. Fabrics and other sheeting used in the construction of tents, booths, stores and similar structures, roof cover...
All gangways and exits from tents should be kept well clear of obstruction
Umer Naqqash
June 18, 2018
However, where a traditional "pole" marquee is to be erected on uneven ground, a solid door frame arrangement may not be suitable ...
The additional following factors should also be considered when siting fire extinguishers.
0
Comments
The additional following factors should also be considered when siting fire extinguishers
Umer Naqqash
June 18, 2018
Extinguishers should normally be sited on escape routes and in similar locations on all floors forming groups to create ‘fire points’. They ...
Electrical fires are not considered to constitute a fire class on their own
Umer Naqqash
June 18, 2018
Electrical Fires Electrical fires are not considered to constitute a fire class on their own, as electricity is a source of ignition that w...
Sprinkler systems are traditionally acknowledged as an efficient means of protecting buildings
0
Comments
Sprinkler systems are traditionally acknowledged as an efficient means of protecting buildings
Umer Naqqash
June 18, 2018
Sprinkler systems are traditionally acknowledged as an efficient means of protecting buildings against extensive damage from fire. They are...
Warehouse (or similar), M or P2/M or P1/M system category A Category M system normally satisfies the requirements of the legislation. It is...
BRADFORD FIRE PREVENTION GROUP
Umer Naqqash
June 18, 2018
M/L5 Automatic fire detectors are sited in such a way as to compensate for the lower standard in other fire precautions. Buildings with ...